Warning

You are reading an old version of this documentation. If you want up-to-date information, please have a look at 2024.6 .

Plugin installation and configuration

The plugin is delivered in a .zip folder. Unzip it and you will find the library and other elements.

  • Library_PluginSiemensProfinetAsycube.al15_1

  • Several folders

The library contains the following elements

../../../_images/content_of_the_library.png

Fig. 197 Content of the library

Installation of the library

  1. Click on Open global library to add an existing library to your project.

../../../_images/add_library.png

Fig. 198 Add library

  1. Add the Library_PluginSiemensProfinetAsycube.al15_1.

Add the Gateway in the configuration

  1. Once your library is installed, expand the Master copies folder and drag and drop the Gateway configuration in the Devices & networks section. Should you have several Gateways, repeat this operation several times.

../../../_images/add_gateway_configuration.png

Fig. 199 Add Gateway configuration

  1. Link the Gateway to desired network.

../../../_images/gateway_linked.png

Fig. 200 Gateway linked

  1. Import HOLDING_REGISTER_READ and HOLDING_REGISTER_WRITE structures from the library to the PLC data types folder.

../../../_images/add_PLC_data_types.png

Fig. 201 Add PLC data types

  1. Import the PLC Tags table Gateway from the library to the PLC Tags folder. Should you have several Gateways, import the tag many times.

../../../_images/add_the_tables_of_variables.png

Fig. 202 Add the table of variables

Connect the registers to the FB

Here is an example of an application with the input and output registers filled in. You must connect the PROFINET status register of the gateway to the input of each FB that you are using as well as the input and output registers of the Asycube.

../../../_images/example_of_integration.png

Fig. 205 Example of integration