Warning

You are reading an old version of this documentation. If you want up-to-date information, please have a look at 2024.6 .

Danger

Backlight

Important

The Backlight from the Asycube 50/80 is not constructed to be used permanently. Please switch off the illumination after image acquisition. There is an auto-switch OFF after 30 seconds of timeout. If this timeout is not respected there is a risk of damaging irreparably the backlight. The duty cycle must stay below 33% (30s ON, 60s OFF).

Caution

Possibly hazardous optical radiation emitted from this product. Do not stare at operating lamp. May be harmful to the eye.

Note

The wave length of the backlight depends on the option ordered, see Backlight

Caution

For safety information regarding the backlight, refer to Backlight synchronization

Temperature

Caution

../../_images/danger_temperature.png

The active elements into the Asycube make the surfaces shown on the picture heating up to 45°C in nominal use. This temperature can nevertheless increase to 55°C in extreme use.

../../_images/specific_warning_80.png

It is the responsibility of customers to document their own application and instruct employees on procedures to avoid contact with these surfaces.

Sound level

Important

This section only concern the users of Asycube 380/530.

Caution

The sound level of the Asycube during intensive use without components on the platform is less than 72 dB. Depending on the components distributed on the platform, the sound level may be higher. In this case, it is the customer’s or integrator’s responsibility to implement the necessary measures to meet the safety requirements for operators.