?42 - Get platform remaining duration

Command

?42

Returns

?00042:<duration>, where

  • <duration> is the remaining hopper vibration time in milliseconds.

Description

This command is used to know the remaining duration until the end of the platform vibration. The value is in milliseconds.

Usage Example

In the example below, the remaining vibration duration is 10 milliseconds.

Command : ?42
Response : ?00042:00010

Note

Before the platform starts to vibrate, the value is fixed to a given value related to the amplifier activation delay (typical values are 60 or 1). During the vibration, the value indicates the remaining time and decrements to 0 to inform that the vibration is finished.