RP4 - Get alarm

Command

RP4

Returns

RP00004:<alarm>, where

  • <alarm> is the activated alarm

Description

The alarms are described in the table below. Use the command WP5=0 to clear the alarms.

Define

Value

Comment

ALARM_PLATFORM

0x01

Platform above max temperature

ALARM_HOPPER

0x02

hopper above max temperature (only for Asycube 50/80)

ALARM_AMPLIFIER

0x04

Amplifier fault (only for Asycube 380/530)

ALARM_PURGE

0x08

The purge has not been closed before the timeout

ALARM_NO_S_POWER

0x10

No S-Power

ALARM_6

0x20

N.C

ALARM_BACK_LT

0x40

Backlight timeout reached

ALARM_8

0x80

N.C

Usage Example

In the example below, the alarm platform 0x01 and alarm hopper 0x02 are activated

Command : RP4
Response : RP00004:00003