Warning
You are reading an old version of this documentation. If you want up-to-date information, please have a look at 2024.6 .Introduction
Overview of the communication plugin
The Asycube-Rockwell-EtherNet/IP plugin is dedicated to control one or several Asycube using pre-programmed Add-On instructions on a Rockwell PLC through a pre-configured EtherNet/IP Gateway.
The plugin provides the following functionalities:
Add-On instruction to trigger the execution of a vibration sequence and to trigger the backlight. (AO_Execute_Sequence).
Add-On instruction to trigger the execution of a platform vibration (standard or centering). (AO_Execute_Platform_Vibration).
Add-On instruction to trigger the execution of a hopper vibration (standard or quantity adjusted) (AO_Execute_Hopper_Vibration).
Add-On instruction to trigger the backlight in different mode (continuous of flash) (FB_Backlight).
Compatibility
The plugin is compatible with any Asycube with a firmware version ≥v4.0.0 The plugin can be used on any system using Studio 5000 31.00.01 or higher. (for the plugin)
General notice
The use of the function blocks does not prevent the use of Asycube Studio to configure the Asycube and parametrize the vibration.
This documentation assumes that you are familiar with Asycube system and know how to configure the recipes.
This documentation also assumes that you are familiar with Rockwell PLCs and know how to use and program them.