Installation and storage

Installation environment

Caution

The Asycube must be mounted on a smooth, flat and strong surface. Ensure yourself that the Asycube is not submitted to mounting flexure. Failure to do so would degrade feeder’s performance and cause mechanical hazard. For more information please refer to the mechanical integration

The Asycube 50/80 can be used under following conditions:

Table 2 Environmental conditions for Asycube 50/80

Parameters

Specifications

Storage Temperature

+5°C to 40°C

Operating Temperature

+5°C to 40°C

Humidity

Operating: 30% to 80% non-condensing

Ingress Protection

IP20

Caution

In the case humidity or temperature variation, note that it might affect the global performances of the Asycube and cause electrical hazard.

Important

  • Do not use the product in an atmosphere of corrosive gases. Rust may form and reduce the structural strength of the product.

  • Avoid extreme electromagnetic waves, ultraviolet rays and radiation.

  • Avoid using the product in a place where the main unit or controller may be exposed to water or oil droplets.

Note

For cleanroom application, please refer to Certification for cleanroom application

Storage Environment

The storage environment should be similar to the operating environment. In addition, the Asycube should be protected from the dust.