Electrical interfaces
Asycube is a standalone module with its own controller. The electrical interfaces of the Asycube are located at the back of the product. The electrical interfaces of the Asycube Clean 230 are located underneath the product.

Fig. 26 Electrical interfaces to the Asycube 50/80
(A) Power connection
(B) Communication Ethernet connection (RJ45)

Fig. 27 Electrical interfaces to the Asycube 240
(A) Power connection
(B) Communication Ethernet connection (RJ45)
(D) Digital input 1
(E) Digital input 2

Fig. 28 Electrical interfaces to the Asycube 380/530
(B) Digital input 1
(C) Digital input 2
(D) Digital and analog Output 1 for hopper
(E) Digital and analog Output 2 for hopper
(F) Power connection
(G) Fuse
(H) Ethernet connection (RJ45)
(I) Purge connector
(J) Programming connection (RJ12) (reserved for Asyril internal use).

Fig. 29 Electrical interfaces to the Asycube Clean 230
(A) Power connection
(B) Communication Ethernet connection (RJ45)
(C) Backlight synchronization (not available as the Asycube Clean 230 has no integrated backlight)
(D) Digital input 1
(E) Digital input 2
Note
The cables are not part of the feeder but can be ordered separately. Please, refer to the the cables chapter.