Warning

You are reading an old version of this documentation. If you want up-to-date information, please have a look at 2023.9 .

Transportation, handling and installation

Packaging of the product,transportation and handling

The product must be transported in accordance with the specifications indicated on the package (top, bottom, fragile, etc.). In addition, the following points must be strictly respected:

  • Take adequate precautions during handling.

  • Do not climb on the package.

  • Never place heavy objects on the package.

  • Take particular care to avoid damaging the product during transportation.

  • If the shipping box is to be left standing, it should be in a horizontal position.

The Asycube is shipped in a cardboard of the following dimensions:

Table 1 Gross weight and dimensions of the product when packaged

Asycube 50

Asycube 80

Asycube 240

Asycube 380

Asycube 530

Dimensions (mm)

500x330x130

500x330x130

460x320x230

680x400x450

800x500x550

Gross weight

4kg

5kg

12 kg

≈ 28 kg

≈ 50 kg

Note

If the items received do not match to your order or are damaged, do not sign the receipt and contact Asyril as soon as possible.

Unpacking instructions

Before unpacking:

  • Ask the transporter to be present at the time of unpacking.

  • Pay particular attention to the external condition of the product.

  • If any damage is noted, do not sign the receipt and contact Asyril immediately.

Note

If the products received do not match your delivery note, or are delivered in poor condition, do not sign the receipt and contact Asyril as soon as possible.

Note

Keep the packaging material and the shipment box in case of return.

Locate the identification sticker at the back of the product and ensure that the product you have received is the appropriate one.

Important information is on this sticker; such as the power consumption or the serial number that you will need for any kind of correspondence with Asyril.

../../_images/product_sticker.png

Fig. 2 Product sticker

Installation environment

Caution

The Asycube must be mounted on a smooth, flat and strong surface. Ensure yourself that the Asycube is not submitted to mounting flexure. Failure to do so would degrade feeder’s performance and cause mechanical hazard. For more information please refer to the mechanical integration

The Asycube can be used under following conditions:

Characteristic

Value

Storage Temperature

+5°C to 40°C

Operating Temperature

+5°C to 40°C

Humidity

Operating: 30% to 80% non-condensing

Ingress Protection

IP20

Caution

In the case humidity or temperature variation, note that it might affect the global performances of the Asycube and cause electrical hazard.

  • Avoid extreme electromagnetic waves, ultraviolet rays and radiation.

  • Avoid using the product in a place where the main unit or controller may be exposed to water or oil droplets.

  • Clean room application: cleanliness class ISO7

Important

Do not use the product in an atmosphere of corrosive gases. Rust may form and reduce the structural strength of the product.

Storage Environment

The storage environment should be similar to the operating environment. In addition, the Asycube should be protected from the dust.