Warning
You are reading an old version of this documentation. If you want up-to-date information, please have a look at 2024.6 .Transportation, handling and installation
Packaging of the product,transportation and handling
The product must be transported in accordance with the specifications indicated on the package (top, bottom, fragile, etc.). In addition, the following points must be strictly respected:
Take adequate precautions during handling.
Do not climb on the package.
Never place heavy objects on the package.
Take particular care to avoid damaging the product during transportation.
If the shipping box is to be left standing, it should be in a horizontal position.
The Asycube is shipped in a cardboard of the following dimensions:
Asycube 50 |
Asycube 80 |
Asycube 240 |
Asycube 380 |
Asycube 530 |
|
---|---|---|---|---|---|
Dimensions (mm) |
500x330x130 |
500x330x130 |
460x320x230 |
680x400x450 |
800x500x550 |
Gross weight |
4kg |
5kg |
12 kg |
≈ 28 kg |
≈ 50 kg |
Note
If the items received do not match to your order or are damaged, do not sign the receipt and contact Asyril as soon as possible.
Unpacking instructions
Before unpacking:
Ask the transporter to be present at the time of unpacking.
Pay particular attention to the external condition of the product.
If any damage is noted, do not sign the receipt and contact Asyril immediately.
Note
If the products received do not match your delivery note, or are delivered in poor condition, do not sign the receipt and contact Asyril as soon as possible.
Note
Keep the packaging material and the shipment box in case of return.
Locate the identification sticker at the back of the product and ensure that the product you have received is the appropriate one.
Important information is on this sticker; such as the power consumption or the serial number that you will need for any kind of correspondence with Asyril.
Installation environment
Caution
The Asycube must be mounted on a smooth, flat and strong surface. Ensure yourself that the Asycube is not submitted to mounting flexure. Failure to do so would degrade feeder’s performance and cause mechanical hazard. For more information please refer to the mechanical integration
The Asycube can be used under following conditions:
Characteristic |
Value |
---|---|
Storage Temperature |
+5°C to 40°C |
Operating Temperature |
+5°C to 40°C |
Humidity |
Operating: 30% to 80% non-condensing |
Ingress Protection |
IP20 |
Caution
In the case humidity or temperature variation, note that it might affect the global performances of the Asycube and cause electrical hazard.
Avoid extreme electromagnetic waves, ultraviolet rays and radiation.
Avoid using the product in a place where the main unit or controller may be exposed to water or oil droplets.
Clean room application: cleanliness class ISO7
Important
Do not use the product in an atmosphere of corrosive gases. Rust may form and reduce the structural strength of the product.
Storage Environment
The storage environment should be similar to the operating environment. In addition, the Asycube should be protected from the dust.