Warning
You are reading an old version of this documentation. If you want up-to-date information, please have a look at 2024.6 .Digital outputs 1 and 2
Important
This section only concern users of Asycube 240, 380 and 530.
A standard M8 four-pins male cable enables to transmit digital output signal and analog output signal to one or two hoppers or the purge for the Asycube 240. It must be connected as follows :
Tip
For more information, please refer to Electrical interfaces.
Note
On the Asycube 240 the purging option requires the use of digital input 2.
Pin |
Signal |
Hopper |
---|---|---|
(1) |
0V GND |
Analog Output 1 |
(2) |
0…10VDC |
|
(3) |
0V GND |
Digital Output 1 |
(4) |
+24 VDC |
Connector type (on Asycube side) : M8, 4P, female.