Warning

You are reading an old version of this documentation. If you want up-to-date information, please have a look at 2024.6 .

Digital outputs 1 and 2

Important

This section only concern users of Asycube 240, 380 and 530.

A standard M8 four-pins male cable enables to transmit digital output signal and analog output signal to one or two hoppers or the purge for the Asycube 240. It must be connected as follows :

Tip

For more information, please refer to Electrical interfaces.

../../_images/digital_output_for_hoppers.png

Fig. 28 Digital output for hoppers

Note

On the Asycube 240 the purging option requires the use of digital input 2.

Pin

Signal

Hopper

(1)

0V GND

Analog Output 1

(2)

0…10VDC

(3)

0V GND

Digital Output 1

(4)

+24 VDC

Connector type (on Asycube side) : M8, 4P, female.