Warning
You are reading an old version of this documentation. If you want up-to-date information, please have a look at 2024.12 .Plugin installation and configuration
The plugin is delivered in a .zip
folder. Unzip it and you will find a folder containing the files/programs
displayed on Fig. 176 and the EDS file for this Gateway.
Installation of the library
The library contains 2 sample programs and 4 function blocks listed below.
We recommend you working with the sample program Sample_Program_Asycube_Standard
which contains everything that is
necessary to implement the scenario introduced in Integration examples. An example of integration of
the other AddOns is described in the Sample_Program_Asycube_Advanced
.
To import a sample program, right click on your task, select Add and choose Import Program…. You will still have to link the Gateway Controller Tags to your AO as described in Link I/O.
Should you want to make a customized integration of the AddOns, you can import them separately by right clicking on the Add-On Instructions folder and choosing Import Add-On Instructions.
Add the Gateway in the configuration
Launch the EDS Hardware Installation Tool
Click on Next
Select Register an EDS file and click on Next
Select the Gateway EDS file delivered in with the library. The name of the file is
HILSCHER NT 100-RE EIS V1.1.EDS
.
Press 4 times on the button Next. Installation of the EDS file is done.
By being online with the PLC, right click on your Ethernet board and add a new module on your I/O Configuration.
Select the Gateway and press Create. Write
NT 100
in the search area to find the Gateway. Should you have several Gateways, you will have to redo step 6 to 7 several times.
Tip
Should you have multiple Gateways, refer to Change IP of the Gateway (If several Gateways are connected to the same PLC) to set a different IP address for each Gateway.
In the tab General, press on Change … and configure 21 Inputs (INT) and 33 Outputs (INT). You can modify the name of the Gateway (in the blue rectangle). This name will be used as reference in the Controller Tags.
Note
Should you have several Gateways, each of them must of course have a different name.
Configure the IP settings. The default IP Address of the Gateway (port
X2-IN
) is192.168.127.254
.
Tip
Should you have multiple Gateways, refer to Change IP of the Gateway (If several Gateways are connected to the same PLC) to set a different IP address for each Gateway.
Link I/O
Once the gateway has been successfully integrated in your project, you will be able to retrieve the registers (data) of
the gateway in the Controller Tags. These registers can then be linked with the I/O from your AO
regAsycubeWritePIO
and regAsycubeReadPIO
as shown in the next section.
Connect the registers to the AO
Here is an example of an application with the input and output registers filled in.
Change IP of the Gateway (If several Gateways are connected to the same PLC)
An Ethernet/IP fieldbus slave (Adapter device) is identified on the Ethernet/IP network based on its IP Address. The IP
Address of the Ethernet/IP Asycube Gateway is set by default to 192.168.127.254
. If several Gateways exist in the
same Ethernet/IP network, the IP Address of some Gateways needs to be modified. Some dedicated tools can persistently
modify the IP Address of the device, such as the
Molex Industrial Communication Competence Center (ICCC) EtherNet/IP Tool.
Note
Please note that the IP Address persists even if the Gateway configuration is reset to the factory settings.
Important
The Hilscher Sycon Software Tool must not be used to change the IP address of the Gateway.