AO_Execute_Sequence
Inputs and Outputs description
This Add-On instruction can be used to trigger the execution of a vibration sequence. This Add-On instruction also allows to turn ON or OFF the backlight of the Asycube. One instance of this instruction is used per Asycube.
図 189 AO_Execute_Sequence
Variable  | 
Type  | 
説明  | 
|---|---|---|
  | 
Boolean  | 
A rising edge starts the sequence.  | 
  | 
Boolean  | 
A rising edge stops the sequence.  | 
If the system is in   | 
||
  | 
Integer  | 
Vibration ID (0..25)  | 
  | 
Integer  | 
Vibration recipe ID (1..26)  | 
  | 
Integer  | 
Number of remaining parts currently on the Asycube.  | 
  | 
Integer  | 
Desired number of parts that you want on the Asycube.  | 
  | 
Integer  | 
X Coordinate of the center of mass of the remaining parts (-100..100). Corresponds to 100x the values described in the coordinate system for the center of mass.  | 
  | 
Integer  | 
Y Coordinate of the center of mass of the remaining parts (-100..100). Corresponds to 100x the values described in the coordinate system for the center of mass.  | 
  | 
Boolean  | 
Turns ON and OFF the backlight  | 
  | 
Boolean  | 
Connection fault status of the gateway.  | 
Variable  | 
Type  | 
説明  | 
|---|---|---|
  | 
Integer  | 
State : 0 = Idle, 1 = Running, 2 = Stopping, 10 = Error  | 
  | 
Boolean  | 
A rising edge indicates the end of the sequence  | 
  | 
Boolean  | 
State:   | 
  | 
Double Integer  | 
Remaining time of the sequence  | 
  | 
Boolean  | 
Goes to   | 
  | 
Integer  | 
Error ID (See Error List)  | 
  | 
String  | 
Error Description (See Error List)  | 
Variable  | 
Type  | 
説明  | 
|---|---|---|
  | 
Integer[0..33]  | 
This input must be linked to the GVL structure containing the write registers (See Plugin installation and configuration to import the structure)  | 
  | 
Integer[0..33]  | 
This input must be linked to the GVL structure containing the read registers (See Plugin installation and configuration to import the structure)  | 
Error List
N°  | 
ID  | 
Cause  | 
Resolution  | 
|---|---|---|---|
700  | 
Transition error  | 
Input that was activated is not allowed in the current state.  | 
Only use command when you are in the correct state.  | 
701  | 
Modbus error  | 
Refer to 主な Modbus 例外コード  | 
|
702  | 
Internal Modbus error  | 
Refer to ホールディング・レジスタ:エラーコード  | 
|
703  | 
Warning  | 
Refer to アジキューブの警告とアラーム  | 
|
704  | 
アラーム  | 
Refer to アジキューブの警告とアラーム  | 
|
705  | 
Gateway disconnected from PLC  | 
Communication problem on the Ethernet/IP segment  | 
Check the cable between gateway and PLC  | 
706  | 
Asycube disconnected from gateway  | 
Communication problem on the Modbus TCP segment  | 
Check the cable between gateway and Asycube  | 
707  | 
Time out  | 
Connection was lost with the Asycube  | 
Check the cables. Check that the Asycube is supplied. Check the Gateway state.  | 
708  | 
Wrong parameter  | 
Wrong input parameter  | 
Correct the wrong input parameter.  | 
709  | 
-  | 
該当なし  | 
-  | 
注釈
The AO_Execute_Sequence block should not be instantiated simultaneously with the 3 following blocks (i.e. FB_Backlight, AO_Execute_Hopper_Vibration, AO_Execute_Platform_Vibration), otherwise, this would result in a "Communication error".
AO_Execute_Platform_Vibration
This Add-On instruction is used to execute a single platform vibration. Standard vibration or centering vibration can be triggered using this instruction.
Inputs and Outputs description
図 190 AO_Execute_Platform_Vibration
Variable  | 
Type  | 
説明  | 
|---|---|---|
  | 
Integer  | 
Mode: 0 = Standard vibration, 1 = Centering vibration  | 
  | 
Boolean  | 
A rising edge starts the vibration.  | 
  | 
Boolean  | 
A rising edge stops the vibration. If the system is in   | 
  | 
Integer  | 
Vibration ID (0..25)  | 
  | 
Integer  | 
Vibration recipe ID (1..26)  | 
  | 
Integer  | 
X Coordinate of the center of mass of the remaining parts (-100..100). Corresponds to 100x the values described in the coordinate system for the center of mass. Only if Mode = 1.  | 
  | 
Integer  | 
Y Coordinate of the center of mass of the remaining parts (-100..100). Corresponds to 100x the values described in the coordinate system for the center of mass. Only if Mode = 1.  | 
  | 
Double Integer  | 
Duration of vibration (0 = unlimited). Only if Mode = 0.  | 
  | 
Boolean  | 
Connection fault status of the gateway  | 
Variable  | 
Type  | 
説明  | 
|---|---|---|
  | 
Integer  | 
State : 0 = Idle, 1 = Running, 2 = Stopping, 10 = Error  | 
  | 
Boolean  | 
A rising edge indicates the end of the sequence  | 
  | 
Double Integer  | 
Remaining time of the vibration.  | 
  | 
Boolean  | 
Goes to   | 
  | 
Integer  | 
Error ID (See Error List)  | 
  | 
String  | 
Error Description (See Error List)  | 
Variable  | 
Type  | 
説明  | 
|---|---|---|
  | 
Integer[0..33]  | 
This input must be linked to the GVL structure containing the write registers (See Plugin installation and configuration to import the structure)  | 
  | 
Integer[0..33]  | 
This input must be linked to the GVL structure containing the read registers (See Plugin installation and configuration to import the structure)  | 
Error List
N°  | 
ID  | 
Cause  | 
Resolution  | 
|---|---|---|---|
710  | 
Transition error  | 
Input that was activated is not allowed in the current state.  | 
Only use command when you are in the correct state.  | 
711  | 
Modbus error  | 
Refer to 主な Modbus 例外コード  | 
|
712  | 
Internal Modbus error  | 
Refer to ホールディング・レジスタ:エラーコード  | 
|
713  | 
Warning  | 
Refer to アジキューブの警告とアラーム  | 
|
714  | 
アラーム  | 
Refer to アジキューブの警告とアラーム  | 
|
715  | 
Gateway disconnected from PLC  | 
Communication problem on the Ethernet/IP segment  | 
Check the cable between gateway and PLC  | 
716  | 
Asycube disconnected from gateway  | 
Communication problem on the Modbus TCP segment  | 
Check the cable between gateway and Asycube  | 
717  | 
Time out  | 
Connection was lost with the Asycube  | 
Check the cables. Check that the Asycube is supplied. Check the Gateway state.  | 
718  | 
Wrong parameter  | 
Wrong input parameter  | 
Correct the wrong input parameter.  | 
719  | 
-  | 
該当なし  | 
-  | 
AO_Execute_Hopper_Vibration
This function block is used to execute a single hopper vibration. Standard vibration or Quantity Adjusted vibration can be triggered using this block.
Inputs and Outputs description
図 191 AO_Execute_Hopper_Vibration
Variable  | 
Type  | 
説明  | 
|---|---|---|
  | 
Integer  | 
Mode: 0 = Standard vibration, 1 = Centering vibration  | 
  | 
Boolean  | 
A rising edge starts the vibration.  | 
  | 
Boolean  | 
A rising edge stops the vibration. If the system is in   | 
  | 
Integer  | 
Vibration ID (0..25)  | 
  | 
Integer  | 
Vibration recipe ID (1..26)  | 
  | 
Integer  | 
Number of remaining parts currently on the Asycube. Only if Mode = 1  | 
  | 
Integer  | 
Desired number of parts that you want on the Asycube. Only if Mode = 1.  | 
  | 
Double Integer  | 
Duration of vibration (0 = unlimited). Only if Mode = 0.  | 
  | 
Boolean  | 
Connection fault status of the gateway  | 
Variable  | 
Type  | 
説明  | 
|---|---|---|
  | 
Integer  | 
State: 0 = IDLE, 1 = Running, 2 = Stopping, 10 = Error  | 
  | 
Boolean  | 
A rising edge indicates the end of the vibration.  | 
  | 
Double Integer  | 
Remaining time of the vibration.  | 
  | 
Boolean  | 
Goes to   | 
  | 
Integer  | 
Error ID (See Error List)  | 
  | 
String  | 
Error Description (See Error List)  | 
Variable  | 
Type  | 
説明  | 
|---|---|---|
  | 
Integer[0..33]  | 
This input must be linked to the GVL structure containing the write registers (See Plugin installation and configuration to import the structure)  | 
  | 
Integer[0..33]  | 
This input must be linked to the GVL structure containing the read registers (See Plugin installation and configuration to import the structure)  | 
Error List
N°  | 
ID  | 
Cause  | 
Resolution  | 
|---|---|---|---|
720  | 
Transition error  | 
Input that was activated is not allowed in the current state.  | 
Only use command when you are in the correct state.  | 
721  | 
Modbus error  | 
Refer to 主な Modbus 例外コード  | 
|
722  | 
Internal Modbus error  | 
Refer to ホールディング・レジスタ:エラーコード  | 
|
723  | 
Warning  | 
Refer to アジキューブの警告とアラーム  | 
|
724  | 
アラーム  | 
Refer to アジキューブの警告とアラーム  | 
|
725  | 
Gateway disconnected from PLC  | 
Communication problem on the Ethernet/IP segment  | 
Check the cable between gateway and PLC  | 
726  | 
Asycube disconnected from gateway  | 
Communication problem on the Modbus TCP segment  | 
Check the cable between gateway and Asycube  | 
727  | 
Time out  | 
Connection was lost with the Asycube  | 
Check the cables. Check that the Asycube is supplied. Check the Gateway state.  | 
728  | 
Wrong parameter  | 
Wrong input parameter  | 
Correct the wrong input parameter.  | 
729  | 
-  | 
該当なし  | 
-  | 
FB_Backlight
This Add-On instruction is used to control the backlight. Backlight can be controlled in continuous or in flash mode.
Inputs and Outputs description
図 192 AO_Backlight
Variable  | 
Type  | 
説明  | 
|---|---|---|
  | 
Boolean  | 
A rising edge turns ON the backlight  | 
  | 
Boolean  | 
A rising edge turns OFF the backlight If the system is in   | 
  | 
Double Integer  | 
Duration of the backlight. If 0, backlight turns OFF only if   | 
  | 
Boolean  | 
Connection fault status of the gateway.  | 
Variable  | 
Type  | 
説明  | 
|---|---|---|
  | 
Word  | 
State: 0 = IDLE, 1 = Running, 2 = Stopping, 10 = Error  | 
  | 
Double Integer  | 
Remaining time of backlight. If   | 
  | 
Boolean  | 
Goes to   | 
  | 
Integer  | 
Error ID (See Error List)  | 
  | 
String  | 
Error Description (See Error List)  | 
Variable  | 
Type  | 
説明  | 
|---|---|---|
  | 
Integer[0..33]  | 
This input must be linked to the GVL structure containing the write registers (See Plugin installation and configuration to import the structure)  | 
  | 
Integer[0..33]  | 
This input must be linked to the GVL structure containing the read registers (See Plugin installation and configuration to import the structure)  | 
Error List
N°  | 
ID  | 
Cause  | 
Resolution  | 
|---|---|---|---|
730  | 
Transition error  | 
Input that was activated is not allowed in the current state.  | 
Only use command when you are in the correct state.  | 
731  | 
Modbus error  | 
Refer to 主な Modbus 例外コード  | 
|
732  | 
Internal Modbus error  | 
Refer to ホールディング・レジスタ:エラーコード  | 
|
733  | 
Warning  | 
Refer to アジキューブの警告とアラーム  | 
|
734  | 
アラーム  | 
Refer to アジキューブの警告とアラーム  | 
|
735  | 
Gateway disconnected from PLC  | 
Communication problem on the Ethernet/IP segment  | 
Check the cable between gateway and PLC  | 
736  | 
Asycube disconnected from gateway  | 
Communication problem on the Modbus TCP segment  | 
Check the cable between gateway and Asycube  | 
737  | 
Time out  | 
Connection was lost with the Asycube  | 
Check the cables. Check that the Asycube is supplied. Check the Gateway state.  | 
739  | 
-  | 
該当なし  | 
-  |