Warning

You are reading an old version of this documentation. If you want up-to-date information, please have a look at 2024.6 .

Gateway connection

Power connection

Connect the 24VDC (130 mA) power supply on the naked plug provided with the Gateway

../../../_images/gateway_power_supply_cc_link.png

Fig. 121 Gateway power supply

Asycube connection

Connect the Gateway X2-IN port to the Asycube communication port with a RJ45 cable (See Fig. 122). The Asycube feeder MUST have its IP Address set to its default value 192.168.127.254. The IP Address of the Gateway X3 port is 192.168.127.1

../../../_images/gateway_ethernet_connection_cc_link.png

Fig. 122 Gateway Ethernet connection

Connect the Gateway to the machine controller

Connect the Gateway X3 port to the machine controller CC-Link with a CC-Link cable.

../../../_images/gateway_cc_link_connection.png

Fig. 123 Gateway CC-Link connection

Power ON

Switch the power supply ON to supply both the Asycube and the Gateway. Check the status of the Gateway LEDs:

  • SYS: steady green ON.

  • APL: blinking green with 2s OFF and 0.5s ON or steady green ON (if the machine controller runs).

  • X2 LINK IN (CH0) L/A: steady green or blinking green.

  • X3 LINK: steady green.

  • Other LEDs may also switch on or blink.

../../../_images/gateway_overview_cc_link.png

Fig. 124 Gateway Overview

Modify the station address

In some cases, you will have to modify the station address of the Gateway. The station address is defined by the two hardware switches. The address ranges from 1 to 64. Use a small flat screwdriver to turn the switches to the desired address.

../../../_images/hardware_switch_change.png

Fig. 125 Hardware switch to change the station address