Vous lisez une ancienne version de cette documentation. Si vous souhaitez obtenir des informations actualisées, veuillez consulter 2025.09 .RP4 - Get alarm
Command
RP4
Returns
RP00004:<alarm>, where
- <alarm>is the activated alarm
Description
The alarms are described in the table below. Use the command WP5=0 to clear the alarms.
| Define | Valeur | Comment | 
| ALARM_PLATFORM | 0x01 | Platform above max temperature | 
| ALARM_HOPPER | 0x02 | hopper above max temperature (only for Asycube 50/80) | 
| ALARM_AMPLIFIER | 0x04 | Amplifier fault (only for Asycube 380/530) | 
| ALARM_PURGE | 0x08 | The purge has not been closed before the timeout | 
| ALARM_NO_S_POWER | 0x10 | No S-Power | 
| ALARM_6 | 0x20 | N.C | 
| ALARM_BACK_LT | 0x40 | Backlight timeout reached | 
| ALARM_8 | 0x80 | N.C | 
Usage Example
In the example below, the alarm platform 0x01 and alarm hopper 0x02 are activated
Command : RP4
Response : RP00004:00003