Register list

Table 46 List of registers

Address

Register name

Read/Write

Data Range

0

HR_MODBUS_CONTROL

W

0 to 15

1

HR_PLATFORM-VIBRATION_TRIG

W

0 or 1

2

HR_PLATFORM_VIBRATION_ID

W

0 to 25

3

HR_PLATFORM_VIBRATION_DURATION

W

0 to 30000 [ms]

4

HR_PLATFORM_CENTERING_TRIG

W

0 or 1

5

HR_PLATFORM_CENTERING_X

W

-100 to 100

6

HR_PLATFORM_CENTERING_Y

W

-100 to 100

7

HR_HOPPER_VIBRATION_TRIG

W

0 or 1

8

HR_HOPPER_VIBRATION_ID

W

0 to 25

9

HR_HOPPER_VIBRATION_DURATION

W

0 to 30000 [ms]

10

HR_HOPPER_FEEDING_TRIG

W

0 or 1

11

HR_HOPPER_FEEDING_VIBRATION

W

0 to 25

12

HR_HOPPER_FEEDING_NBPARTS

W

0 to 65535

13

HR_HOPPER_FEEDING_NBMAX

W

0 to 65535

14

HR_SEQUENCE_EXECUTION_TRIG

W

0 or 1

15

HR_SEQUENCE_EXECUTION_NBPARTS

W

0 to 65535

16

HR_SEQUENCE_EXECUTION_NBMAX

W

0 to 65535

17

HR_SEQUENCE_EXECUTION_X

W

-100 to 100

18

HR_SEQUENCE_EXECUTION_Y

W

-100 to 100

19

HR_SEQUENCE_EXECUTION_SEQUENCEID

W

1 to 26

20

HR_SELECT_VIBRATION_SET

W

1 to 26

21

HR_SELECT_SEQUENCE

W

1 to 26

22

HR_BACKLIGHT_STATE_CONTROL

W

0 or 1

23

HR_EXECUTE_BACKLIGHT_FLASH_TRIG

W

0 or 1

24

HR_BACKLIGHT_INTENSITY_TRIG

W

0 or 1

25

HR_BACKLIGHT_INTENSITY

W

min to 100 [%]

26

HR_PLATFORM_HALT

W

0 or 1

27

HR_HOPPER_HALT

W

0 or 1

28

HR_SEQUENCE_HALT

W

0 or 1

29

HR_READ_WRITE_PARAMETER_TRIG

W

0 or 1

30

HR_READ_WRITE_PARAMETER_ADDRESS

W

0 to 65535

31

HR_READ_WRITE_PARAMETER_WRITE_VALUE

W

0 to 65535

32

HR_FLASH_OPERATIONS

W

0 to 15

64+0

HR_MODBUS_STATUS

R

0 to 15

64+1

HR_MODBUS_ERROR_CODE

R

0 to 65535

64+2

HR_WARNINGS

R

0 to 255

64+3

HR_ALARMS

R

0 to 255

64+4

HR_MODBUS_PLATFORM_STATUS

R

0 to 2

64+5

HR_PLATFORM_REMAINING_TIME

R

0 to 32767 [ms]

64+6

HR_MODBUS_HOPPER_STATUS

R

0 to 2

64+7

HR_HOPPER_REMAINING_TIME

R

0 to 32767 [ms]

64+8

HR_MODBUS_SEQUENCE_STATUS

R

0 to 2

64+9

HR_SEQUENCE_REMAINING_TIME

R

0 to 32767 [ms]

64+10

HR_VIBRATION_SET_SELECTED

R

1 to 26

64+11

HR_SEQUENCE_SELECTED

R

1 to 26

64+12

HR_BACKLIGHT_STATE_STATUS

R

0 or 1

64+13

HR_READ_WRITE_PARAMETER_READ_VALUE

R

0 to 65535

64+14

HR_FIRMWARE_VERSION_H

R

0 to 9

64+15

HR_FIRMWARE_VERSION_M

R

0 to 9

64+16

HR_FIRMWARE_VERSION_L

R

0 to 9

64+17

HR_USER_ACCESS_LEVEL

R

0 to 4

64+18

HR_FLASH_OPERATIONS_STATUS

R

0 or 1

64+19

HR_MODBUS_COMMUNICATION_STATUS_L

R

0 to 4

64+20

HR_MODBUS_COMMUNICATION_STATUS_H

R

0

64+21

HR_ETHERCAT_COMMUNICATION_STATUS

R

0 to 65535

All the registers in the Table 46 are described in the Asycube Modbus Register Table.

Registers 64+19 and 64+20 are specific to this Gateway.

HR_MODBUS_COMMUNICATION_STATUS_L (64+19) and HR_MODBUS_COMMUNICATION_STATUS_H (64+20)

These registers contain the state of the Modbus TCP communication.

Table 47 Modbus TCP communication states

Value°

State

Description

0

Unknown

-

1

Offline

-

2

Stop

-

3

Idle

Not connected

4

Operate

Connected and working properly

HR_ETHERCAT_COMMUNICATION_STATUS (64+21)

This register contains the state of the EtherCAT communication.

Table 48 EtherCAT communication state

Value °

Description

0x0008

OP - Connected and working properly

0x0101

Slave not present

Table 48 is not exhaustive, further information about EtherCAT communication can be found on Beckhoff’s website.