Avertissement

Vous lisez une ancienne version de cette documentation. Si vous souhaitez obtenir des informations actualisées, veuillez consulter 2024.12 .

Connexion de l’alimentation électrique

Important

  • Before supplying power to the Asycube, check that your distribution voltage is the same as the nominal voltage (24 VDC).

  • Utilisez une alimentation nominale PELV (protected extra-low voltage).

  • Incorrect wiring of 0V and 24V can cause irreparable damages and void the warranty.

  • Strictly follow the power supply recommendations described in this section for your Asycube type.

../../_images/power_connection_50_80_240_380_530.png

Fig. 21 Connecteur d’alimentation Asycube 50/80/240 (gauche) ; Asycube 380/530 (droite)

Tableau 3 Power connector pinout

Pôle

Description du signal

Câble (option)

(1)

Alimentation-S 24 VDC PELV

1

(2)

Alimentation-S 0V GND

2

(3)

Alimentation 24 VDC

3

(4)

Courant 0V GND

4

(5)

TERRE

PE

Tableau 4 Power connector type

50/80/240

380/530

Type de connecteur (côté Asycube)

M16, 5 pôles, mâle

Harting 09 12 005 3004

Tableau 5 Power ratings

Characteristics

Asycube 50/80

Asycube 240

Asycube 380

Asycube 530

Tension

24 VDC +5%

24 VDC +5%

24 VDC +5%

24 VDC +5%

Current consumption on Power

5 A

5 A

4 A [1]

6 A [1]

Current consumption on S-Power

1 A

3 A

16 A [1]

14 A [1]

Consommation totale de courant

6 A

8 A

20 A

20 A

Remarque

Both Power and S-Power can be connected to a single power supply or to two different power supplies. Select your power supplies with a nominal current rating as recommended in Tableau 5 with a current reserve of 150% for 3 seconds. The 0 V-GND and Earth signals of the two supplies are connected inside the Asycube.

Remarque

S-Power is the safety power for the backlight. Cutting S-Power ensures that the backlight stays OFF.

The following connection schematic shows the way to connect the Asycube depending if your application requires using an external relay to ensure that the backlight is safely switched off or not. In any case, both Power and S-Power have to be supplied for using the backlight.

../../_images/power_connection_without_or_with_safety_relay_50_80.png

Fig. 22 Connexion électrique sans et avec relais de sécurité