Vous lisez une ancienne version de cette documentation. Si vous souhaitez obtenir des informations actualisées, veuillez consulter 2025.09 .Asycube Modbus Register Table
Asycube data can be accessed via Modbus TCP through Holding Registers. The registers presented in this section describes all the Asycube Holding Registers.
All Holding Registers are 2 bytes long. Their type is generally a WORD
or an UNSIGNED_INT16. Some of the Holding Registers can have negative values(see Data Range specification for each
register).In this case, their type is SIGNED_INT16.
All registers are either Read-only or Write-only. The registers addresses are shown with the address offset of the zone and the relative address of the register (e.g. “64+3” means that the register is in the zone starting at address 64).
Control Holding Registers (Write-only zone, offset=0)
The Control Holding Registers are used to control the Asycube. For example, start a vibration, start a sequence, clear the errors, …
- 0 - HR_MODBUS_CONTROL
- Data Range : 0 to 15 - The 4 first bits are used to clear the errors. A rising edge on a bit clears the corresponding error. More information in Modbus errors. 
- 1 - HR_PLATFORM_VIBRATION_TRIG
- Data Range : 0 or 1 - A rising edge triggers the start of a platform vibration with the parameters values given in HR_PLATFORM_VIBRATION_ID and HR_PLATFORM_VIBRATION_DURATION. 
- 2 - HR_PLATFORM_VIBRATION_ID
- Data Range : 0 to 25 - The platform vibration identifier is used when a platform vibration is triggered with HR_PLATFORM_VIBRATION_TRIG. The value 0 corresponds to the vibration - A, the value 3 corresponds to the vibration- D, … Refer to Types of vibration to find the corresponding direction.
- 3 - HR_PLATFORM_VIBRATION_DURATION
- Data Range : 0 to 30000 [ms] - This value lets the user chose the duration of the platform vibration when it is triggered with HR_PLATFORM_VIBRATION_TRIG. 
- 4 - HR_PLATFORM_CENTERING_TRIG
- Data Range : 0 or 1 - A rising edge (value change from 0 to 1) triggers the start of a platform centering with the parameters values given in HR_PLATFORM_CENTERING_X and HR_PLATFORM_CENTERING_Y. More information in EC - Execute centering. 
- 5 - HR_PLATFORM_CENTERING_X
- Data Range : -100 to 100 - The platform centering triggered with HR_PLATFORM_CENTERING_TRIG uses this X position to determine both the vibration direction and the duration. This value is an integer and corresponds to 100x the value described in the coordinate system for the center of mass; a value of -60 in this Holding Register corresponds to -0.6 in the defined coordinate system. 
- 6 - HR_PLATFORM_CENTERING_Y
- Data Range : -100 to 100 - The platform centering triggered with HR_PLATFORM_CENTERING_TRIG uses this Y position to determine both the vibration direction and the duration. This value is an integer and corresponds to 100x the value described in the coordinate system for the center of mass; a value of -60 in this Holding Register corresponds to -0.6 in the defined coordinate system. 
- 7 - HR_HOPPER_VIBRATION_TRIG
- Data Range : 0 or 1 - A rising edge triggers the start of a hopper vibration with the parameters values given in HR_HOPPER_VIBRATION_ID and HR_HOPPER_VIBRATION_DURATION. 
- 8 - HR_HOPPER_VIBRATION_ID
- Data Range : 0 to 25 - The hopper vibration identifier is used when a hopper vibration is triggered with HR_HOPPER_VIBRATION_TRIG. The value 0 corresponds to the vibration - A. When using Asycube Studio, only the vibration- Ais configured.
- 9 - HR_HOPPER_VIBRATION_DURATION
- Data Range : 0 to 30000 [ms] - This value lets the user chose the duration of the hopper vibration when it is triggered with HR_HOPPER_VIBRATION_TRIG. 
- 10 - HR_HOPPER_FEEDING_TRIG
- Data Range : 0 to 15 - A rising edge triggers the start of a hopper feeding with the parameters values given in HR_HOPPER_FEEDING_VIBRATION, HR_HOPPER_FEEDING_NBPARTS and HR_HOPPER_FEEDING_NBMAX. More information in EF - Execute feeding. 
- 11 - HR_HOPPER_FEEDING_VIBRATION
- Data Range : 0 to 25 - The hopper feeding triggered with HR_HOPPER_VIBRATION_TRIG uses this hopper vibration identifier. The value 0 corresponds to the vibration - A. When using Asycube Studio, only the vibration- Ais configured.
- 12 - HR_HOPPER_FEEDING_NBPARTS
- Data Range : 0 to 65535 - The hopper feeding triggered with HR_HOPPER_VIBRATION_TRIG uses this number of parts. More information in EF - Execute feeding. 
- 13 - HR_HOPPER_FEEDING_NBMAX
- Data Range : 0 to 65535 - The hopper feeding triggered with HR_HOPPER_VIBRATION_TRIG uses this maximum number of parts. More information in EF - Execute feeding. 
- 14 - HR_SEQUENCE_EXECUTION_TRIG
- Data Range : 0 or 1 - A rising edge triggers the start of a sequence execution with the parameters values given in HR_SEQUENCE_EXECUTION_NBPARTS, HR_SEQUENCE_EXECUTION_NBMAX, HR_SEQUENCE_EXECUTION_X, HR_SEQUENCE_EXECUTION_Y and HR_SEQUENCE_EXECUTION_SEQUENCEID. More information in ES - Execute sequence. 
- 15 - HR_SEQUENCE_EXECUTION_NBPARTS
- Data Range : 0 to 65535 - The sequence execution triggered with HR_SEQUENCE_EXECUTION_TRIG uses this number of parts. More information in ES - Execute sequence. 
- 16 - HR_SEQUENCE_EXECUTION_NBMAX
- Data Range : 0 to 65535 - The sequence execution triggered with HR_SEQUENCE_EXECUTION_TRIG uses this maximum number of parts. More information in ES - Execute sequence. 
- 17 - HR_SEQUENCE_EXECUTION_X
- Data Range : -100 to 100 - The sequence execution triggered with HR_SEQUENCE_EXECUTION_TRIG uses this X position to determine both the vibration direction and the duration. This value is an integer and corresponds to 100x the value described in the coordinate system for the center of mass; a value of -60 in this Holding Register corresponds to -0.6 in the defined coordinate system. 
- 18 - HR_SEQUENCE_EXECUTION_Y
- Data Range : -100 to 100 - The sequence execution triggered with HR_SEQUENCE_EXECUTION_TRIG uses this Y position to determine both the vibration direction and the duration. This value is an integer and corresponds to 100x the value described in the coordinate system for the center of mass; a value of -60 in this Holding Register corresponds to -0.6 in the defined coordinate system. 
- 19 - HR_SEQUENCE_EXECUTION_SEQUENCEID
- Data Range : 1 to 26 - The sequence execution triggered with HR_SEQUENCE_EXECUTION_TRIG uses this sequence ID. More information in ES - Execute sequence. 
- 20 - HR_SELECT_VIBRATION_SET
- Data Range : 1 to 26 - A value change of this Holding Register sets the new vibration recipe to use. 
- 21 - HR_SELECT_SEQUENCE
- Do not use - for Asyril internal use only 
- 22 - HR_BACKLIGHT_STATE_CONTROL
- Data Range : 0 or 1 - A rising edge switches the backlight ON. A falling edge (value change from 1 to 0) switches the backlight OFF. 
- 23 - HR_EXECUTE_BACKLIGHT_FLASH_TRIG
- Data Range : 0 or 1 - A rising edge triggers a backlight flash. More information in Rétroéclairage. 
- 24 - HR_BACKLIGHT_INTENSITY_TRIG
- Data Range : 0 or 1 - A rising edge sets the backlight intensity value given in the Holding Register HR_BACKLIGHT_INTENSITY. 
- 25 - HR_BACKLIGHT_INTENSITY
- Data Range : min to 100 [%] - This backlight intensity can be set by triggering the HR_BACKLIGHT_INTENSITY Holding Register. The min value corresponds to the minimum intensity settable for the Asycube, which value can be read using the TCP/IP command - {RP104}.
- 26 - HR_PLATFORM_HALT
- Data Range : 0 or 1 - A rising edge halts the platform vibration. 
- 27 - HR_HOPPER_HALT
- Data Range : 0 or 1 - A rising edge halts the hopper vibration. 
- 28 - HR_SEQUENCE_HALT
- Data Range : 0 or 1 - A rising edge halts the sequence execution. 
- 29 - HR_READ_WRITE_PARAMETER_TRIG
- Do not use - for Asyril internal use only 
- 30 - HR_READ_WRITE_PARAMETER_ADDRESS
- Do not use - for Asyril internal use only 
- 31 - HR_READ_WRITE_PARAMETER_WRITE_VALUE
- Do not use - for Asyril internal use only 
- 32 - HR_FLASH_OPERATIONS
- Do not use - for Asyril internal use only 
Status Holding Registers (Read-only zone, offset=64)
The Status Holding Registers presented in this chapter are used to get information on the Asycube. Examples: remaining vibration time, error state, …
- 64 + 0 - HR_MODBUS_STATUS
- Data Range : 0 to 15 - The 4 first bits represents the errors status: Asycube Modbus errors status, Internal Modbus communication error status, Asycube warnings status and Asycube alarms status. More information in Errors. 
- 64 + 1 - HR_MODBUS_ERROR_CODE
- Data Range : 0 to 65535 - The lower byte (mask - 0x00FF) of this Holding Register contains Asycube Modbus error code, while the upper byte (mask- 0xFF00, the upper byte must be shifted right 8 bits to be interpreted correctly) contains the Internal Modbus communication error code. More information in Holding Register: error codes.
- 64 + 2 - HR_WARNINGS
- Do not use - for Asyril internal use only 
- 64 + 3 - HR_ALARMS
- Data Range : 0 to 255 - This Holding Register contains the Asycube alarm code. More information in Alarms. 
- 64 + 4 - HR_MODBUS_PLATFORM_STATUS
- Data Range : 0: DONE / 1: BUSY / 2: ERROR - This Holding Register gives the status of either the platform vibration triggered with HR_PLATFORM_VIBRATION_TRIG or the platform centering triggered with HR_PLATFORM_CENTERING_TRIG. - The transition DONE->BUSY occurs on the trigger rising edge if the data is correct. 
- The transition DONE->ERROR occurs on the trigger rising edge if the data is incorrect (e.g. index is out of range). 
- The transition BUSY->DONE occurs as soon as the vibration ends. 
- The transition BUSY->ERROR occurs if an Internal Modbus communication error (see Holding Register: error codes) before the vibration starts. 
- The transition ERROR->DONE can be controlled by setting both triggers to 0. 
 
- 64 + 5 - HR_PLATFORM_REMAINING_TIME
- Data Range : 0 to 32767 [ms] - This Holding Register gives the remaining time of the platform vibration. During a vibration, the value decreases over time until it reaches 0. - Remarque - A value of 32767 means that the remaining time is greater than 32767ms. - Remarque - Just before the vibration starts, during the amplifier start up, the value is different than 0 but can be strange. Similarly, during a continuous vibration, the value stays different than 0 but can be strange. 
- 64 + 6 - HR_MODBUS_HOPPER_STATUS
- Data Range : 0: DONE / 1: BUSY / 2: ERROR - This Holding Register gives the status of either the hopper vibration triggered with HR_HOPPER_VIBRATION_TRIG or the hopper feeding triggered with HR_HOPPER_FEEDING_TRIG. - The transition DONE->BUSY occurs on the trigger rising edge if the data is correct. 
- The transition DONE->ERROR occurs on the trigger rising edge if the data is incorrect (e.g. index is out of range). 
- The transition BUSY->DONE occurs as soon as the vibration ends. 
- The transition BUSY->ERROR occurs if an Internal Modbus communication error (see Holding Register: error codes) before the vibration starts. 
- The transition ERROR->DONE can be controlled by setting both triggers to 0. 
 
- 64 + 7 - HR_HOPPER_REMAINING_TIME
- Data Range : 0 to 32767 [ms] - This Holding Register gives the remaining time of the hopper vibration. During a vibration, the value decreases over time until it reaches 0. - Remarque - A value of 32767 means that the remaining time is greater than 32767ms. - Remarque - Just before the vibration starts, during the amplifier start up, the value is different than 0 but can be strange. Similarly, during a continuous vibration, the value stays different than 0 but can be strange. 
- 64 + 8 - HR_MODBUS_SEQUENCE_STATUS
- Data Range : 0: DONE / 1: BUSY / 2: ERROR - This Holding Register gives the status of the sequence execution triggered with HR_SEQUENCE_EXECUTION_TRIG. - The transition DONE->BUSY occurs on the trigger rising edge if the data is correct. 
- The transition DONE->ERROR occurs on the trigger rising edge if the data is incorrect (e.g. index is out of range). 
- The transition BUSY->DONE occurs as soon as the sequence ends. 
- The transition BUSY->ERROR occurs if an Internal Modbus communication error (see Holding Register: error codes) before the sequence starts. 
- The transition ERROR->DONE can be controlled by setting the trigger to 0. 
 
- 64 + 9 - HR_SEQUENCE_REMAINING_TIME
- Data Range : 0 to 32767 [ms] - This Holding Register gives the remaining time of the sequence execution. During a sequence, the value decreases over time until it reaches 0. - Remarque - A value of 32767 means that the remaining time is greater than 32767ms. 
- 64 + 10 - HR_VIBRATION_SET_SELECTED
- Data Range : 1 to 26 - This Holding Register gives the current selected vibration recipe. 
- 64 + 11 - HR_SEQUENCE_SELECTED
- Data Range : 1 to 26 - This Holding Register gives the current selected vibration recipe. 
- 64 + 12 - HR_BACKLIGHT_STATE_STATUS
- Data Range : 0: OFF / 1: ON - This Holding Register gives the current backlight state. 
- 64 + 13 - HR_READ_WRITE_PARAMETER_READ_VALUE
- Do not use - for Asyril internal use only 
- 64 + 14 - HR_FIRMWARE_VERSION_H
- Do not use - for Asyril internal use only 
- 64 + 15 - HR_FIRMWARE_VERSION_M
- Do not use - for Asyril internal use only 
- 64 + 16 - HR_FIRMWARE_VERSION_L
- Do not use - for Asyril internal use only 
- 64 + 17 - HR_USER_ACCESS_LEVEL
- Do not use - for Asyril internal use only 
- 64 + 18 - HR_FLASH_OPERATIONS_STATUS
- Do not use - for Asyril internal use only